Self Leveling Underlayments
Self-leveling underlayment is a class of surface preparation materials used by tile and floor covering tile installers to prepare level setting beds for carpet, vinyl, hardwood, and ceramic. Most Self-leveling underlayments that are suitable for use with ceramic or stone tile are made for interior, dry-area installations. Generally, they are site-mixed powders mixed with water or latex, poured and distributed evenly over a prepared substrate, and allowed to cure and harden. Following the cure, some Self-leveling underlayment surfaces must be sealed with a primer for any type of installation, and a crack isolation/waterproofing membrane for wet-area applications.
Not all Self-leveling underlayment materials are suitable or recommended for ceramic tile installations, and not all are underlayment grade, and some may only be suitable for patching structurally sound plywood subfloor/plywood underlayment or concrete construction. There are no manufacturing or installation standards for Self-leveling underlayment materials, which in this article, refer to those self-leveling materials that when properly installed, can substitute for a mortar bed, backer board, or plywood underlayment on wood construction projects.
Self-leveling underlayment have long been partnered with the restoration of concrete slabs contaminated by curing compound or other surface-ingrained materials: after removing the top 3/8- to 1-inch of the surface of the affected concrete with bush-hammer, abrader, or shot-blaster, the resulting rough surface is sealed with a primer and covered with a thin topping of Self-leveling underlayment. Some Self-leveling underlayment materials can be used over wood construction, but only as a surface preparation treatment for structurally sound plywood subfloor/plywood underlayment combinations– not as an underlayment.
Why Use a Self-leveling Underlayment?
In the past, practically all surfaces to be tiled were neither flat nor level. The reason being that the tile installer’s mortar beds would provide a level and flat setting bed for the tiles. Today, an installer with mortar bed skills can make quick work of leveling a floor that does not meet minimum standards, but while mortar beds are still a viable method for leveling a floor or plumbing a wall, the labor force to perform such work is dwindling. As a result, self-leveling products were developed. From my own experience (and I am a person who takes great pride in his mortar beds), I would rather save my mortar bed skills for sloped floors and for wall or ceiling work: for either wood or concrete floors, I prefer to use Self-leveling underlayment materials for obvious reasons – they level themselves – but also for the not-so-obvious. With a Self-leveling underlayment, density of the setting bed is very uniform, but with mortar beds, even those that are compacted, density can sometimes be a problem – especially if mortar is used to support hydronic tubing. In my opinion, as long as they are installed properly, Self-leveling underlayment materials can provide surface smoothness and compressive strengths far in excess of most mortar beds.
For concrete restoration work, the use of an Self-leveling underlayment or SLC is obvious, but on wood construction, there are a number of underlayment choices including plywood, backer boards, or an Self-leveling underlayment. The selection process begins at the subfloor: does it meet or exceed the industry standards for flat and level? If so, plywood or backer boards will provide a reasonable level of finish quality. But if the subfloor is out of level, and the installation spec calls for a surface that meets the minimum standards, a Self-leveling underlayment can be a best buy when compared to the cost of correcting either the structure or the plywood or backer board underlayments. All three underlayment choices require considerable labor to be installed properly, and all may carry considerable loads, but unless costly structural or surface corrections are made to fix a problem substrate, only a Self-leveling underlayment can ensure a level surface.
Another application where a Self-leveling underlayment makes good practical and economic sense is when an electrical resistance tile warming system is installed beneath the tiles. Many tile-warming systems permit direct application of tile over the heating mat with medium-bed thinset mortar, but this method puts the integrity of the heating element at risk. Instead, cover the heating mat with a Self-leveling underlayment, let it cure and harden, and then install the tiles – this eliminates accidents during the tiling portion of the installation.
Whether or not a radiant heat system is incorporated into the Self-leveling underlayment installation, there are several general guidelines to follow:
- Scrupulous surface preparation and a clean substrate are paramount.
- Movement joints are mandatory.
- Mixing and distribution must be tightly controlled.
Self-leveling underlayment materials must be fully cured before covering with membrane or tile.
Surface Prep
With concrete, most Self-leveling underlayment installations require removal of the surface of the concrete down to a specified depth. For example, new concrete contaminated by curing compound needs to have approximately 3/8” of its surface removed. Old concrete contaminated by exposure to hot oils might require removal of up to 1” of the surface. Concrete cured without a compound, but produced with a slick, steel-troweled finish might require that only 1/16” of the surface be removed. Some Self-leveling underlayment mixes require a primer or reinforcing mesh (or both) for concrete and plywood applications. For best results, rehabbing of any concrete should not take place until all installation materials are in-hand, and the tiles are ready to be installed.
For wood construction, subfloor plywood should be the proper grade and an appropriate thickness. If you want D+ performance, follow the industry minimum standards: upgrading from 5/8” plywood to 3/4” is highly recommended. A thicker subfloor may be stronger, but if its surface is contaminated with dirt, grease, paint, etc., the bond, compression, and shear strength of the Self-leveling underlayment will be no greater than if a thinner subflooring was installed – possibly less. For best results, cleanup using a wet/dry vac fitted with a HEPA filter instead of a broom.
Movement Joints Required
One of the most overlooked details of any Self-leveling underlayment installation is the network of movement joints surrounding the floor. Space for the movement joint slot is most practically made by lining the hard perimeter with self-sticking foam tape. The faces of the foam core for both sizes are covered with thin films of adhesive, which, in turn, are covered with a peel-away, bond-breaking paper tape. To apply, simply peel off one side of the paper and stick the tape to a floor’s perimeter, leaving its other paper skin still attached. After the Self-leveling underlayment is poured, any foam tape located above the plane of the floor can be slit through with a sharp knife and peeled or scraped off the wall. In wet-area applications, I remove all the foam tape below the plane of the floor after the Self-leveling underlayment has cured, and fill the empty slot with an appropriate sealant before tiling.
Mixing and Distribution
Mixing of any Self-leveling underlayment should not begin until all surface preparation tasks are complete and the floor vacuumed (or damp-mopped) clean. There are several approaches to mixing depending on how much material has to be poured. If only one sack of material is required, I pour the required mixing water into a five-gallon bucket (for 50-pound sacks or less), slowly add the powder, and combine with an electric mixer for the amount of time required by the manufacturer. For more than one sack, use a mixing container large enough to hold up to three sacks (the amount needed to cover a 40-square foot bathroom floor fitted with a tile warming system).
Regardless of size, all Self-leveling underlayment materials need to be distributed around a floor – not just dumped in a pile. For best results, 100% of the floor surface should be wet with mix before allowing the mix’s self-leveling properties to take over. Rapid setting is an important property for some installations, but I prefer using slow setting brands because they are capable of providing a smoother, flatter surface than rapid types.
Curing
Finally, all Self-leveling underlayment materials must be given the time and the environment to cure properly. This means providing minimum temperatures before, during, and after the pour (until the end of the curing period, actually), keeping direct sunlight off the fresh Self-leveling underlayment surface until curing has finished, keeping dust or paint overspray off the Self-leveling underlayment surface, keeping the pour free of shock, vibrations, or stress until the end of the cure, and honoring the time requirements provided by each brand’s manufacturer.
Novoplan 2 is a high-strength Professional self-leveling underlayment, self-leveling cement-based underlayment and repair mix for interior concrete and engineer-approved floors.
Novoplan Easy is a high-strength Easy-preparation, self-leveling underlayment, self-leveling cement-based underlayment and repair mix for interior concrete and engineer-approved floors. It typically requires only a clean, soundly bonded substrate before application. Novoplan Easy provides low installation costs and fast turnaround on job sites.
Ultraplan Easy is an HCT™ (High-Hydrated Cement Technology)-based, quick-setting High-Performance, Easy-Preparation, Self-Leveling Underlayment, self-leveling underlayment that typically requires only a clean, soundly bonded substrate before application. Typically requiring reduced surface preparation, Ultraplan Easy provides lower installation costs and fast turnaround on job sites. It features high strength and is able to withstand light foot traffic after 2 to 3 hours of installation.
Ultraplan 1 Plus is an HCT™ (High-Hydrated Cement Technology)-based High-performance, quick-setting, self-leveling underlayment, quick-setting, self-leveling, self-drying underlayment and repair mix for interior concrete and engineer-approved floors. It has high strength and is abrasion-resistant, able to withstand light foot traffic after 2 to 3 hours and vehicular rubber-wheel traffic after 3 days.